PAGE 7 of 24 AUDIO/VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1.0
Art.850
The 850 transformer includes a 13Vac (1A max.) output and a 24Vac (1A max.) output.
Each of the two outputs is individually fused.
CONNECTIONS
Art. 893N
Art.701
20Vdc 800mA continuous 1A surge PSU and is used as a booster
supply or when more than two videophones are required in an
apartment. This power supply only has an output when either a 0V
is applied to –C or when a voltage is applied to +C. At all other
times the + output is switched off.
Connection Function
230V~ 0 Mains voltage input
+ Switched 20Vdc output (Triggered by –C or +C)
- 0V
-C 0V trigger input (From 4V to 0V)
+C + volts trigger input (From 8V up to 30V)
D+ Switched +20Vdc output via diode
BST/GMT digital time clock. This time clock operates from a 12Vac
or dc power supply. The output is a dry contact relay. When used
with this system the trade button input is used. This allows the dry
contact relay to drive the lock release directly. The relay can be
programmed to release the lock for 1 – 99 seconds.
Connection Function
+ 12Vac or dc voltage input
- 0V
TR Trade button input (Switched 0V)
C Common connection on relay
NO Normally open connection on relay
NC Normally closed connection on relay
For more information see time clock instruction sheet
Terminal Function
24V 24V ac output
13V 13V ac output
230V Live mains connection In
0 Neutral mains connection In
Fuse